ATC-157 - AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, wide temperature range,excellent...
Request Quote
For Price
- Part Number:
- ATC-157
- Model Number:
- ATC-157
- Make:
- AMETEK TEST & CALIBRATION INSTRUMENTS
- Lead Time:
- Available
- Qty In Stock:
- Available
AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, wide temperature range,excellent stability, Enhanced stability and high accuracy. Simple Type: Temperature Calibrator
The JOFRA ATC series (Advanced Temperature Calibrators) combines the accuracy of laboratory temperature sources with the speed and portability of field dry-block calibrators. The unique dual-zone design sets new standards for optimum temperature performance in dry-block calibrators.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Display indicator: for temperature uniformity Shows the degree of temperature uniformity in the insert when using the new DLC technology. B and C models only
- DLC (Dynamic Load Compensation): Perfect temperature uniformity in the insert, even when calibrating large sensors or many sensors at a time. B and C models only
- EURAMET: Best performing dry-block with regard to the EURAMET/cg-13/v.01 guideline for testing of dry blocks
- Excellent stability 0.005°C
- High accuracy: Down to ±0.04°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used.
- Improved temperature homogeneity: Unique active dual-zone block ensures good temperature homogeneity in the calibration zone
- Intelligent reference sensors: JOFRA reference sensors are supplied with intelligent plugs, holding the calibration data (coefficients) of the reference sensor. This is a truly plug’n’play calibration
- USB communication:All RTC calibrators communicate via an easy-to-use USB port
- Wide temperature range: RTC-156 from -30 to 155°C (-22 to 311°F) RTC-157 from -45 to 155°C (-49 to 311°F)
Specifications
- Frequency, non US deliveries: 50 Hz ±5, 60 Hz ±5
- Frequency, US deliveries: 60 Hz ±5
- Power consumption (max.): 400 W
- RTC-156 @ ambient temp. 0°C/32°F: -46 to 155°C/-51 to 311°F
- RTC-156 @ ambient temp. 23°C/73°F: -30 to 155°C/-22 to 311°F
- RTC-156 @ ambient temp. 40°C/104°F: -15 to 155°C/ 5 to 311°F
- RTC-156/157: 290 g/10.2 oz
- RTC-156/157 inner diameter (multi hole): 25.6 mm/1.01 in
- RTC-156/157 length: 150 mm/5.91 in
- RTC-156/157 outer diameter: 29.7 mm/1.17 in
- RTC-157 @ ambient temp. 0°C/32°F: -57 to 155°C/-71 to 311°F
- RTC-157 @ ambient temp. 23°C/73°F: -45 to 155°C/-49 to 311°F
- RTC-157 @ ambient temp. 40°C/104°F: -31 to 155°C/-24 to 311°F
- Switch input (B model only) Test current: Maximum 2.5 mA
- Switch input (B model only) Test voltage: Maximum 5 VDC
- Transmitter supply Output current: Maximum 28 mA
- Transmitter supply Output voltage: 24VDC ±10%
- Voltage: 115V (90-127) / 230V (180-254)
- Voltage input VDC (B model only) Accuracy (12 months): ±(0.005% Rdg. +0.010% F.S.)
- Voltage input VDC (B model only) Range: 0 to 12 VDC
- Weight and instrument size (L x W x H) RTC-156/157: 10.5 kg/23.2 lb
- Weight and instrument size (L x W x H) RTC-156/157: 362 x 171 x 363 mm/14.3 x 6.7 x 14.3 in
Applications
- None Available
Aliases