AMETEK TEST & CALIBRATION INSTRUMENTS Industrial P

ATC-157 - AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, wide temperature range,excellent...

larger image

Request Quote
For Price
Part Number:
ATC-157
Model Number:
ATC-157
Make:
AMETEK TEST & CALIBRATION INSTRUMENTS
Lead Time:
Available
Qty In Stock:
Available

AMETEK TEST & CALIBRATION INSTRUMENTS, Temperature calibrator, wide temperature range,excellent stability, Enhanced stability and high accuracy. Simple Type: Temperature Calibrator

The JOFRA ATC series (Advanced Temperature Calibrators) combines the accuracy of laboratory temperature sources with the speed and portability of field dry-block calibrators. The unique dual-zone design sets new standards for optimum temperature performance in dry-block calibrators.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Display indicator: for temperature uniformity Shows the degree of temperature uniformity in the insert when using the new DLC technology. B and C models only
  • DLC (Dynamic Load Compensation): Perfect temperature uniformity in the insert, even when calibrating large sensors or many sensors at a time. B and C models only
  • EURAMET: Best performing dry-block with regard to the EURAMET/cg-13/v.01 guideline for testing of dry blocks
  • Excellent stability 0.005°C
  • High accuracy: Down to ±0.04°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used.
  • Improved temperature homogeneity: Unique active dual-zone block ensures good temperature homogeneity in the calibration zone
  • Intelligent reference sensors: JOFRA reference sensors are supplied with intelligent plugs, holding the calibration data (coefficients) of the reference sensor. This is a truly plug’n’play calibration
  • USB communication:All RTC calibrators communicate via an easy-to-use USB port
  • Wide temperature range: RTC-156 from -30 to 155°C (-22 to 311°F) RTC-157 from -45 to 155°C (-49 to 311°F)

Specifications

    General
  • Frequency, non US deliveries: 50 Hz ±5, 60 Hz ±5
  • Frequency, US deliveries: 60 Hz ±5
  • Power consumption (max.): 400 W
  • RTC-156 @ ambient temp. 0°C/32°F: -46 to 155°C/-51 to 311°F
  • RTC-156 @ ambient temp. 23°C/73°F: -30 to 155°C/-22 to 311°F
  • RTC-156 @ ambient temp. 40°C/104°F: -15 to 155°C/ 5 to 311°F
  • RTC-156/157: 290 g/10.2 oz
  • RTC-156/157 inner diameter (multi hole): 25.6 mm/1.01 in
  • RTC-156/157 length: 150 mm/5.91 in
  • RTC-156/157 outer diameter: 29.7 mm/1.17 in
  • RTC-157 @ ambient temp. 0°C/32°F: -57 to 155°C/-71 to 311°F
  • RTC-157 @ ambient temp. 23°C/73°F: -45 to 155°C/-49 to 311°F
  • RTC-157 @ ambient temp. 40°C/104°F: -31 to 155°C/-24 to 311°F
  • Switch input (B model only) Test current: Maximum 2.5 mA
  • Switch input (B model only) Test voltage: Maximum 5 VDC
  • Transmitter supply Output current: Maximum 28 mA
  • Transmitter supply Output voltage: 24VDC ±10%
  • Voltage: 115V (90-127) / 230V (180-254)
  • Voltage input VDC (B model only) Accuracy (12 months): ±(0.005% Rdg. +0.010% F.S.)
  • Voltage input VDC (B model only) Range: 0 to 12 VDC
  • Weight and instrument size (L x W x H) RTC-156/157: 10.5 kg/23.2 lb
  • Weight and instrument size (L x W x H) RTC-156/157: 362 x 171 x 363 mm/14.3 x 6.7 x 14.3 in

 

Applications

  • None Available

Aliases

  • None Available